Accessories

1. Control unit VG 2
for heaters of driver's cabs in tank vehicles, for the trans-
portation of hazardous goods according to ADR (not to be
used in combination with a time switch).
2. Outside switch AS
for switching the heater on and off from the outside of the
vehicle, e.g. for cargo space heaters (available with 4 m or
10 m connecting cables).
3. Acoustic signalling device ASM
gives an acoustic signal in event of a failure.
4. Time switch ZUE / ZUE 2
for pre-programming 3 switch-on times within 7 days,
including 4 m connecting cable (suitable for 12 V and 24 V
vehicle electrical system).
ZUE, part no. 39890-00, for installation in existing cut-outs,
suitable for control panel with slide switch.
ZUE 2, part no. 39891-00 with cover frame, suitable for
control panel with rotary switch.
5. Remote sensor
monitors the room tem perature independent of the position
of the control panel (available with 4 m or 10 m connecting
cable).
6. Multiple connector MSD
for connecting several accessories (e.g. time switch and
remote sensor).
Extension cable for accessories
items 1 – 6 of 4 m or 10 m (not illustrated).
7. Direct switch DIS 1
for operating the heater at high setting only, without tem-
perature control (available with 10 m connecting cable).
Replaces control panel.
Or direct fixed temperature switch DFS
for operating the heater at a fixed temperature
(40 °C – 70 °C depending on the version). Replaces the
control panel.
All electrical accessories are fitted with a connector and can
be connected individually.
18

Technical data

determined in accordance with EN 624 or Truma test conditions
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Rated thermal output
High setting: 2400 W
Low setting: 1200 W
Gas consumption
High setting: 200 g/h
Low setting: 100 g/h
Air flow rate
High setting: approx. 78 m³/h
Low setting: approx. 49 m³/h
Current input at 12 V
High setting: 1.1 A
Low setting: 0.6 A
Current input at 24 V
High setting: 0.7 A
Low setting: 0.4 A
Standby
0.01 A
Weight
Heater unit:
Heater unit with peripheral devices: 5.1 kg
The right to effect technical modifications is reserved!

Dimensions

370
All dimensions in mm.
4.8 kg