Elpro 27 HP
GB
230 V
ELECTRICAL CONNECTIONS ON SWINGING GATE MODE - dip-switch - B n° 1 = OFF
Accessory
24 Vac output:
V IX 5 3
Gate electric lock:
Output for single-
phase motors
230 V - 1.100 W max -
1,5 HP:
Electric latch and
flashing lamp 230 Vac:
Board power supply
230 V:
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230 V - 50/60 Hz
Electrical connections
24 Vac OUTPUT - max load:
12 13
No. 3 pairs of photocells
No. 1 radio receiver
No. 1 LED Chis 37 / Chis-E 37 key-switch
Instructions are attached to the related control
accessories
Power supply output 12 Vac/dc or 24 Vac/dc for
an electric lock,15 VA max. The electric lock is
14 15
to be fitted onto the gate operated by the M1
motor, delayed in closing cycle.
"STRIP"
JUMPER
Power supply for a mechanical
LOCK
release lock
SETUP
LOCK
Power supply for a magnetic lock
SETUP
to hold the gate/s on gate stop/s
AC
= alternated current output
= direct current output
DC
In case of one motor only:
1) Connect power supply to the terminals motor M1
2) No gate delay in opening by dip-A n° 8 = ON
3) Set the trimmer gate delay in closing to zero
In case of 2 motors:
Gate delay in opening, with a fixed time of 2 s:
if required, it must be enabled by dip-A n° 8 = OFF
16 17
18 19 20 21
M1
M2
motor
delayed
in closing
230 Vac OUTPUT
22 23
for electric latch.
Important: power supply
must be off during dwell time
by dip-A n° 10 = ON
230 Vac OUTPUT
for flashing lamp
max 25 W
Electronic control board power supply
24
25
230 V - 50/60 Hz ± 10%
Dip-switch setting and LED indication of functions
DIP-SWITCH - A N° 8:
motor
delayed
8
in opening
DIP-SWITCH - A N° 4 and N° 10:
4
10
23
ELECTRIC LOCK
TIME
0,5 s - 20 s
3 2 1
12 V electric lock power supply
3 2 1
24 V electric lock power supply
MOTOR RUN TIME
OPEN-CLOSE
0 s - 60 s
DWELL TIME
1 s - 220 s
GATE DELAY
IN CLOSING
0 s - 10 s
ON: no gate delay in opening
OFF: 2 s gate delay in opening enabled
ON: pre-flashing before movement
OFF: no pre-flashing
ON: out of service in dwell phase
automatic mode (by dip 3 = ON)
OFF: powered, ie. in service in dwell phase