Télécharger Imprimer la page

fadini Elpro 27 HP Notice D'instructions page 19

Publicité

Les langues disponibles

Les langues disponibles

Elpro 27 HP
GB
230 V
ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - dip-switch - B n° 1 = ON
Accessory
Power connections
to Pulin 3 LEDs:
24 Vdc - 5 W output:
Single sliding gate limit switches:
In applications where only one motor is fitted,
connect the inputs of the M1 and M2 limit
switches be put in "parallel" (bridge 30 with 33
and 31 with 34, and then connect them to the
limit switches open - close).
IMPORTANT:
if no limit switches, are involved, link out
terminals 30 - 31 - 32 - 33 - 34. Limit switches
(L-sw.) must have normally closed contacts
Double sliding gate limit switches:
In applications where two motors are fitted, connect the normally
closed limit switches to the respective input terminals.
IMPORTANT: if no limit switches are involved, link out terminals
30 - 31 - 32 - 33 - 34. Limit switches (L-sw.) must have normally
closed contacts
Traffic lights plug-in card (optional - Item No. 7282L):
The power supply of this card is independent from that of the control board:
230 V - 50 Hz with an output of 100 W at 230 V each lamp.
Logic of operation:
- GREEN light = driveway OPEN
- RED light = driveway CLOSED
- YELLOW light = it switches on before light changes from green to red
Note: in pedestrians mode the traffic light is always RED.
Dip-switch - A
4 = ON Pre-flashing enabled: traffic lights red - yellow - green
4 = OFF Pre-flashing disabled: traffic lights red - green
6 = ON Limit switches installed
6 = OFF Limit switches linked out (functioning by time setting)
Dip-Switch - B
3 = ON Pre-flashing time prolonged by about 2 seconds
(yellow light up to 3 seconds)
3 = OFF Standard time as factory-preset
Functioning with 2 lamps (red and green):
Dip-switch - A
4 = OFF
Dip-switch - A
6 = adjust setting depending on whether the limit switches
are used or not in the installation
Dip-Switch - B
3 = OFF
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230 V - 50/60 Hz
Electrical connections
Terminals for the
3
28 27 26
connections of the LEDs
of the push buttons
Pulin 3
OUTPUT
29 30
24 Vdc - 5 W max
30 31 32 33 34
M1
M2
30 31 32 33
34
19
LED indication of functions
L30 ON = OFF on engaging L.sw. Opening
L31 ON = OFF on engaging L.sw. Closing
L33 ON = OFF on engaging L.sw. Opening
L34 ON = OFF on engaging L.sw. Closing
L30 ON = OFF on engaging L.sw. Opening M1
L31 ON = OFF on engaging L.sw. Closing M1
L33 ON = OFF on engaging L.sw. Opening M2
L34 ON = OFF on engaging L.sw. Closing M2
RED
YELLOW
GREEN
63
64 65 66 60 61
1 A fuse
Red
Yellow
Green
(Optional:
traffic lights plug-in card
for 230 V lamps)
item 7282L

Publicité

loading