fadini Elpro 27 HP Notice D'instructions page 15

Publicité

Les langues disponibles

Les langues disponibles

Elpro 27 HP
GB
230 V
ATTENTION: before starting the electrical connections, select the mode of operation depending on gate type by dip-switch B n° 1 and read the
!
instructions respectively dedicated as follows:
SLIDING gates from page 15 to page 20 - SWINGING gates from page 21 to page 25.
M1
30 31 32 33 34 35
26
L30 L31 L33 L34 L35
27
28
CARD
CONNECTOR FOR
TRAFFIC LIGHTS
(Item 7282L)
ON
OFF
PLUG-IN
RADIO
CARD
CONNECTOR
L
L1
L0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
NC
NC
2
nd
pair
photocells
General description:
the electronic control box Elpro 27 HP - 230 V has been developed to provide a reliable unit to control single or double sliding gate automatic systems with or without
limit switches, as well as single or double swinging gate systems fitted with pressure valves; single-phase 230 V - 50/60 Hz. The manufacturer is not liable for any incorrect
use of this appliance; and also reservesthe right to change and update it without previous notice.
IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:
- The control box must be installed in a dry and sheltered place.
- Make sure that power supply to the control board be 230 V ±10%.
- Make sure that power supply to the electric motor be 230 V ±10%.
- For distances longer than 50 metres increase the section of the wires.
- Fit the mains to the control box with a high sensitivity, 0,03 A, differential, magnetic-thermal circuit breaker.
- Cables with 1,5 mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m.
- Cables with 1 mm² section wires are to be used for the limit switches, photocells, push buttons and accessories.
- If no photocells are used link out terminals 1 and 2.
- If no stop button is used link out terminals 3 and 6.
- Open/close motor run time trimmer must be always superior to the time actually required for the gate travel.
N.W.: For applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected.
Diagnostic LEDs:
L ON = Board on 230 V voltage and F1, F2, F3 fuses all right
nd
L0 ON = 2
pair photocells, not obstructed
st
L1 ON = 1
pair photocells not obstructed
L4 OFF = open, it switches on by any open pulse
L5 OFF = close, it switches on by any close pulse
L6 ON = stop, it switches off by any stop pulse
L7 OFF = radio, it switches on by any pulse from the transmitter/radio contact
L8 OFF = pedestrian mode, it switches on by any pedestrian pulsing
L10 ON = safety edge protecting closing
L30 ON = it switches off when Fc.A. (limit switch Opening = L-sw.O) is engaged, M1
L31 ON = it switches off when Fc.C. (limit switch Closing = L-sw.C) is engaged, M1
L33 ON = it switches off when Fc.A. (limit switch Opening = L-sw.O) is engaged, M2
L34 ON = it switches off when Fc.C. (limit switch Closing = L-sw.C) is engaged, M2
L35 ON = safety edge protecting opening
IN CASE OF FAILURE PLEASE MAKE SURE THAT:
- Power supply to the electronic control box is 230 V ±10%.
- Power supply to the electric motor is 230 V ±10%.
- All of the fuses is all right.
- The photocell contacts are closed.
- No voltage drop has occurred from the Elpro board to the electric motor.
- All of the NC contacts of the control board are all right.
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230 V - 50/60 Hz
Safety edge
OUTPUT CONFIGURATION
M2
in opening
TERMINALS 14 - 15
LOCK
SETUP
- GATE DELAY
JB
DWELL
1 2
TIME
- OPENING FOR
1 s - 220 s
RUN TIME
OPEN - CLOSE
sliding: 0 s - 120 s
swinging: 0 s - 60 s
DIP-SWITCH - A
DIP-SWITCH - B
ON
OFF
1 2 3 4
5 6 7 8 9 10 11 12
1 2 3 4
ELPRO 27
ELPRO 27 HP
E 27
UNL
L4 L5 L6 L7 L8
L10
Power supply
24 V - 50 mA max
3 2 1
F3 = 2 A
24 V
low voltage
circuit
protection
CLOSING: 0 s - 10 s
TRANSFORMER
PEDESTRIANS 1 s - 45 s
ELECTRIC LOCK
TIME
0,5 s - 20 s
COND
COND
M1
M2
20 μF
20 μF
SETUP
JA
EDGE
TYPE
1 2
16 17 18 19 20 21 22 23
M1
M2
ELECTRIC MOTORS
230 V SINGLE-PHASE
Power supply
1.100 W max (1,5 HP)
230 Vac OUTPUT
max 25 W
for flasher
and electric latch
15
F4 = 630 mA
transformer
primary
protection
COURTESY LAMP
230 V MAX 100 W
it goes on when gate
starts and stays on for
a fixed time of 90 seconds
after motor run time expiry
F1 = 16 A
F2 = 16 A
24
25
Control board
power supply
230 V
50/60 Hz ± 10%
NOTE:
the green LEDs must
always be on.
SYMBOLS:
NO contact
NC contact
Resistive contact
8,2 kΩ or NC
Led ON
Led OFF
Pilot light
Flasher