Elpro 27 HP
GB
230 V
FUNCTIONS FOR SLIDING GATE OPENING - dip-switch - B n° 1 = ON
AUTOMATIC / SEMI-AUTOMATIC:
Automatic cycle: by one pulse from the open command the gate opens and stops in dwell mode
for the time as pre-set on the dwell trimmer. When this time expires the gatecloses automatically.
Semi-automatic cycle: by one pulse from the open command the gate opens and stops in fully
open position. To close the gate, a close pulse is needed.
PEDESTRIAN OPENING:
With the gate in fully closed position, a pulse to terminals 3-8
operates the gate for pedestrians.
(On pedestrian mode, it is advisable to set dip-A n° 3 = ON for
automatic re-closing).
The function pedestrian opening is not in service during the first
operation cycle, after a power failure.
RE-CLOSING BY PASSING ACROSS THE PHOTOCELLS:
in opening and dwell cycles (DIP-A N° 3 = ON)
Gate is automatically closed after 3 s from passing between the photocells.
In case a second pair of photocells are installed, (dip-9 = ON), both pairs are to be passed across.
DSA:
PHOTOCELL AUTOMATIC CONTROL
For the DSA control (Device for Safety Auto-test) it is necessary to
connect only the photocell transmitters (TX) to this output and
select dip-B n° 4 = ON: if this function is enabled, Elpro 27 HP - 230 V
checks that all the connected photocell devices are cleared from
obstacles and properly working before starting any door/gate
movements, otherwise the door/gate is not started.
DEADMAN (HOLD-ON-SWITCHED) FUNCTION:
The open/close operations are achieved by holding on a command switched (the relays are not
self-holding) and consequently the user must be actively present during gate movements until
the push-button or the key-switch is released.
PARTY FUNCTION
OPEN-AND-HOLD BY EXTERNAL CLOCK:
Connection: connect the clock NO contact to OPEN
terminals n° 4 and COMMON n° 3, and activate
automatic closing by dip-switch n° 3 = ON.
How it works: program the opening time on the clock.
At the preset time, the gate will open and remain open
(the flashing light will turn off ) and will not accept any
other command (not even radio commands) until the
time set on the clock expires.
When this time expires the gate closes automatically
after the pause time. While the gate is held open by the
time set on the clock, the indication light keeps giving
out two consecutive flashes followed by a long pause.
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230 V - 50/60 Hz
Description
3 4
DIP-SWITCH - A N° 3:
3
RIT. C
OPENING FOR
PEDESTRIANS
1 s - 45 s
DIP-SWITCH - A N° 9 and N° 11:
9
11
DIP-SWITCH - B N° 4:
15
16
4
24 Vac output
for photocell transmitter TX
enabled for DSA control
DIP-SWITCH - B N° 2:
2
DIP-SWITCH - A N° 3:
External time clock
3
IMPORTANT:
use always and only with dip-A N° 3 = ON
NO
20
Dip-switch setting and LED indication of functions
ON: automatic closing
OFF: semi-automatic, closing by pulse
Dwell trimmer: adjust dwell time
on automatic mode from 1 s up to 220 s
L8 OFF = no pedestrian contact given, it goes on
by pulsing for pedestrians
3
4 5 6 7 8
nd
ON: 2
pair photocells enabled
OFF: 2
nd
pair photocells not installed
ON: automatic closing on passing across
the photocells after 3 seconds
OFF: no automatic closing on passing across
the photocells after 3 seconds
ON: DSA safety control enabled
OFF: DSA safety control disabled
ON: deadman control enabled
OFF: deadman control disabled
ON: automatic closing
OPEN
PEDESTRIANS