Télécharger Imprimer la page

fadini Elpro 27 HP Notice D'instructions page 18

Publicité

Les langues disponibles

Les langues disponibles

Elpro 27 HP
GB
230 V
ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - dip-switch - B n° 1 = ON
Accessory
24 Vac output:
V IX 5 3
Gate electric lock:
Output for single-
phase motors
230 V - 1.100 W max -
1,5 HP:
Flasher 230 Vac:
PCB power supply
230 V:
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230 V - 50/60 Hz
Electrical connections
24 Vac OUTPUT - max load:
12 13
No. 3 pairs of photocells
No. 1 radio receiver
No. 1 LED Chis 37 / Chis-E 37 key-switch
Instructions are attached to the related control
accessories
Power supply output 12 Vac/dc or 24 Vac/dc
14 15
for an electric lock, 15 VA max
"STRIP"
JUMPER
Power supply for a mechanical
LOCK
release lock
SETUP
LOCK
Power supply for a magnetic lock
SETUP
to hold the gate/s on gate stop/s
AC
= alternated current output
= direct current output
DC
In case of one motor only:
1) Connect power supply to the terminals motor M1
2) No gate delay in opening by dip-A n° 8 = ON
3) Set the trimmer gate delay in closing to zero
In case of 2 motors:
1) Connect power supply to the terminals motors M1 and M2
2) No gate delay in opening by dip-A n° 8 = ON
3) Set the trimmer gate delay in closing to zero
16 17
18 19 20 21
M1
M2
22 23
230 Vac OUTPUT
flasher
max 25 W
Control board power supply
24
25
230 V - 50/60 Hz ±10%
Dip-switch setting and LED indication of functions
DIP-SWITCH - A N° 4 and N° 10:
4
10
18
ELECTRIC LOCK
TIME
0,5 s - 20 s
3 2 1
12 V electric lock power supply
3 2 1
24 V electric lock power supply
MOTOR RUN TIME
OPEN - CLOSE
0 s - 120 s
DWELL TIME
1 s - 220 s
ON: pre-flashing before movement
OFF: no pre-flashing
ON: flasher out of service in dwell time
automatic mode (dip 3 = ON)
OFF: flasher in service in dwell time
automatic mode (dip 3 = ON)

Publicité

loading