►►7. FUEL FILTER CLEANING
en
See Pic. 4
THE FILTER MAY NEED TO BE CLEANED DEPENDING
it
ON THE QUALITY OF THE FUEL USED.
►7.1. Remove the plug positioned on the tank (A Pic. 4).
de
►7.2. Remove the filter from the tank.
►7.3. Loosen the nut (B Pic. 4).
es
►7.4. Remove the filter (C Pic. 4).
►7.5. Clean the filter with clean fuel; make sure you do
fr
not damage it.
►7.6. Put the filter back in the tank.
nl
pt
da
►►9. DISPLAY ERRORS
fi
See B Pic. 3
no
ERROR
sv
F0
1. The "ON/OFF" switch is turned "ON" (|) when the
heater is plugged in
pl
ru
F1
1. No fuel
cs
2. Fuel is contaminated
hu
3. Photocell is dirty or damaged
4. Fuel filter is dirty
sl
5. Ignition error
tr
F2
1. Interrupted cable
hr
2. Sensor is damaged
lt
F3
1. Internal heater overheating
2. Antitilting sensor intervent
lv
F4
et
1. Incorrect voltage
ro
FF
1. No fuel
2. Dirty fuel filter
sk
3. Dirty or defective photocell
4. Dirty or defective nozzle
bg
5. Anti-tilting sensor trip
uk
PF
1. Flat battery
bs
[ ]
1. Thermostat connected
el
2. Switching from cable to battery power supply
zh
CAUSE
OPERATION ERROR
PHOTOCELL ERROR
TEMPERATURE CONTROL SENSOR ERROR
THERMOSTAT ERROR
INCORRECT VOLTAGE
NO SWITCH-ON AFTER THREE ATTEMPTS
FLAT BATTERY
HEATER IN STAND-BY
►►8. STORAGE AND TRANSPORT
I ORDER TO KEEP AND/OR TRANSPORT THE HEATER
IN THE BEST WAY, THE FOLLOWING PROCEDURE
MUST BE FOLLOWED:
►8.1. Empty the fuel from the tank.
►8.2. If you notice any residue, pour clean fuel into the
tank and rinse again.
►8.3. Close the tank cap and dispose of the fuel
appropriately according to the Standards in force.
►8.4. in order to keep the heater in the best way possible,
it must be kept on a level surface to prevent the escape
of fuel and in a dry place away from any possible ex-
ternal threats.
SOLUTION
1. After disconnecting the heater, see that the switch is in
the "OFF" (0) position, plug the heater in and turn the
switch "ON" (|)
1. Turn the switch "OFF" (0), refill the fuel tank
2. Turn the switch "OFF" (0) empty and refill the fuel tank.
Clean the filter using clean fuel, do not damage the
filter (SEE PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Contact the technical service center
2. Contact the technical service center
1. Turn the heater off, wait until it is cooled down
2. Place the heater on a level and stable surface
1. Check voltage of your electric supply system
1. Contact the technical service center
2. Contact the technical service center
3. Contact the technical service center
4. Contact the technical service center
5. Contact the technical service center
1. Recharge the battery
1. Thermostat temperature set below the room tempera-
ture
2. Automatic re-ignition