CRUIS E
A SS E M B LY
The refrigerators of the Cruise range are pre-set for being assembled in a niche.
Fastening can be done on the front plate band.
It is very important for the refrigerating unit, consisting of the compressor and the condenser, to be well
ventilated, with the cool air coming in from the bottom and going out from the top. You must ensure proper
ventilation of the refrigerating unit. The air inlets and outlets must have a free cross section of at least 200
cm
. (see ventilation diagrams in Fig. 3-4).
2
The model CR.40 - CR.42 – refrigerators are provided with a refrigerating unit which can be separated from
the set and placed at a distance in order to make the best use of the available space (about 200 cm).
Take great care when handling the connection tube in order to prevent breakages (Fig. 5). The compressor
must normally stand in a vertical position, but it will work equally well slanted by up to 30°.
WIRIN G SYS TE M : FUN C TION S AND FE ATU RE S
The Station of the compressor is a piece of electronic equipment which pilots the motor of the compressor
and carried out all the controls and electrical protection of the system. Its main features are the following:
a) Protection of the battery with automatic turning off of the compressor when the feeding voltage reaches
the minimum threshold (cut out)
The compressor will start up automatically again when the voltage goes back to normal values (cut in).
TABLE FOR BATTERY SAVER INTERVENTION VOLTAGES
WIRIN G CO NNEC TIO N S
When you connect the refrigerator, you must remember the following:
1) Use cables having the proper cross section (see the table) to make the feeding lines. If possible, such cables
should be without any joints on the leads which could lead to voltage falls.
2) If the wiring system of the vehicle is insufficient or not properly sized for the refrigerator, we suggest you
connect it directly to the battery.
Note The use of cables having an insufficient cross section may lead to the compressor stopping even when
the battery is charged.
C ROS S SECT IO N
CAB LES MM
2.5
10
3) Any switches must have a breaking load not less than 20 A (10 A if powered at 24 Volt).
4) Make sure the polarity is right: connect the red cable to the positive terminal (+) and the black cable to the
negative terminal (-).
CRUISE_27-02-2019
FEEDING
12 V
24 V
MAXIMUM LENGTH O F CABL E S IN ME TRE S
2
4
6
CUT OUT
CUT IN
9,5 V
11 V
21 V
23 V
12 V
2.5
4
6
10
12
24 V
5
8
12
20