Télécharger Imprimer la page

Parkside 108972 Traduction Des Instructions D'origine page 35

Publicité

Les langues disponibles

Les langues disponibles

using the adapter nozzle
Area of use:
You can insert the adapter nozzle
valve. You will fi nd this together with other valves
(standard valve, screw valve, ...) on large-volume
items, for example an infl atable mattress.
Press the lever quick coupler
attach it.
GB
Insert the nozzle adapter
coupler
and then release it.
Screw the nozzle adapter
nozzle
.
Infl ate as described above.
Maintenance and cleaning
WARNING! RISK OF INJURY! Switch
the appliance off and remove the
power plug before commencing any
work to the appliance.
Do not use any sharp objects to clean the
appliance. Never permit fl uids to penetrate
inside the appliance. The appliance could be
damaged. The carbon brushes should only be
replaced by the service centre or an authorised
specialist workshop. Apart from this, the appli-
ance is maintenance-free.
Ensure that the appliance has cooled down
completely, otherwise there is a risk of burns.
The appliance must be depressurised before
all cleaning and maintenance tasks. To do this,
open the release valve
escapes.
Clean the appliance regularly, preferably im-
mediately after completion of the work.
Clean the housing with a dry cloth – do NOT
use petrol, solvents or cleaners that can attack
the plastic.
Ensure that no water gets into the appliance.
Ventilation openings must never be obstructed.
NOTE
Replacement parts not listed (such as carbon
brushes, switch) can be ordered via our
service hotline.
32
in a vent
downwards to
into the lever quick
into the adapter
until no more air
NOTE
This appliance is maintenance free. Never open
the appliance. The appliance may only be re-
paired by an authorised service centre or Cus-
tomer Service. If one of the faults listed below
occurs, note the following:
Disconnect the appliance from any power
supply.
Allow the appliance to cool down and wait a
short while for the residual energy to neutralise.
Ensure that the appliance is in good working
condition.
Troubleshooting
Fault
Solution
1. Appliance
1. Check your power supply.
does not
Check that all cables, fuses
run
and the mains socket are in
working order.
2. Do not use excessively long
extension cables.
3. Do not use the appliance
at temperatures below
+5 degrees.
4. Avoid overheating the
motor. Allow the motor
to cool down.
2. Working
Check the seals and the non-
pressure
return valve. Replace these if
too low
necessary.
3. Tools do
Check the hoses, quick coupler
not work
and the tools. Replace these if
necessary.
PKZ 180 B2

Publicité

loading

Ce manuel est également adapté pour:

Pkz 180 b2