Noise/Vibration Information
Measured sound values determined according to EN
60745.
Typically the A-weighted noise levels of the product
are: Sound pressure level
level
90.5
dB(A). Uncertainty K=3 dB(A).
Wear hearing protection!
Overall vibrational values (vector sum of three
directions) determined according to EN 60745:
Surface
grinding:
vibration
a
=
6.9
m/s
, uncertainty K=1.5 m/s
2
h, AG
The vibration emission level given in this information
sheet has been measured in accordance with a
standardised test given in EN 60745 and may be
used to compare one tool with another. It may be used
for a preliminary assessment of exposure.
The declared vibration emission level represents
the main applications of the tool. However, if the
accessories or is poorly maintained, the vibration
exposure level over the total working period.
An estimation of the level of exposure to vibration
should also take into account the times when the tool
exposure level over the total working period.
Identify additional safety measures to protect the
the tool and the accessories, keep the hands warm,
organise work patterns.
79.5
dB(A); Sound power
emission
value
.
2
EC-Declaration of conformity
We declare under our sole responsibility that this
product is in conformity with the following standards
or standardisation documents:
EN 60745-1:2009+A11:2010,
EN 60745-2-3: 2011 + A2:2013 + A11:2014 +
A12:2014 +A13:2015,
EN 55014-1:2017,
EN 55014-2:2015,
EN 50581:2012, in accordance with the Directives
2006/42/EC, 2014/30/EU, 2011/65/EU.
Adolf Würth GmbH & Co. Kg, Abt. PPT
Reinhold-Würth-Straße 12 – 17,
74653 Künzelsau, GERMANY
Frank Wolpert
Head of Product Management
Authorized Signatory
Dr.-Ing. Siegfried Beichter
Head of Quality,
Authorized Signatory
Künzelsau: 29.12.2018
Subject to change without notice.
34