2 CAPACITOR VERSION
5.2
PROBLEM
It does not work.
All LEDs off
en
Red LED flashes
a frequency of 1s
Yellow LED flashes
at a frequency of 1s
and the red is fixed
Fixed yellow LED
and fixed red LED
Yellow LED flashes at
a frequency of 1s and
red LED flashes at a
frequency of 1s
Fixed yellow LED and
red flashing at a
frequency of 1s
PROBLEM
The needle makes excessive noise
The needle works normally but
overheats
12
SPYDER PRO
2V 30, 2V 38, 2V 50, 2V 60, 2V 70, 1V 38, 1V 50, 1V 60
LEDS STATUS
G (1)
Y (3)
R (2)
0
0
0
0
0
P1000
0
P1000
1
0
1
1
0
P1000
P1000
0
1
P1000
CAUSE
Defective bearings.
Check that the needle does not work outside the concrete.
Check the input voltage of the converter.
Bearings in poor condition or lack of lubrication.
CAUSE
Check if there is power
Plug in bad condition
Cut power cord
Broken converter
Stator - needle burnt
Broken converter
Stator - needle burnt
The needle has high current demand
Broken converter
Over temperature
Check the cleanliness of the converter, remove
unnecessary coatings if necessary
Remove excess adhered concrete
Input overvoltage (Vac)
Check input voltage
Use a more stable voltage supply
Ground leak
Check the main network ground wire
Check the voltage between neutral and ground
(0 Vac)
FRECUENCY CONVERTER AND POKERS