tape). It is important all the parts are tighten (200 to 400 Nm of torque) to avoid the water does not
penetrate in the head. Finally, apply two weld spots to secure the parts do not loose. Test working 10
minutes on the air and check no leak of oil (no touch after the test it is very hot).
7.
After maintenance jobs all the parts must be assembled correctly.
8.
Every 12 month or more frequently, depending on the use, it is recommended an inspection be done
by an authorised dealer.
9.
Check the wear of the poker controlling the outside diameter and length of the poker. Replace the
housing or cap when the diameter or length in the least point is less than the specified in the table
according to the model:
M3 AFP
M38 AFP
M5 AFP
M6 AFP
M7 AFP
a.
b.
c.
d.
en
STORAGE
4.8
When the converter has not been used for long periods of time, it should be stored in clean, dry and protected
areas.
TRANSPORTATION
4.9
When transporting by vehicles, ensure the equipment is safe against slipping, overturning and blow
10
SPYDER PRO
2V 30, 2V 38, 2V 50, 2V 60, 2V 70, 1V 38, 1V 50, 1V 60
Model
Diameter(mm)
28 (30)
36,5 (38)
48 (50)
56 (58)
63 (65)
The minimum dimensions are bold printed
The dimensions into brackets are the original dimensions
Replace the housing when reach the minimum diameter
Replace the cap when reach the minimum length
Length (mm)
347 (353)
365 (370)
360 (365)
395 (400)
395 (400)
FRECUENCY CONVERTER AND POKERS