Defrost water
The cabinet produces water during defrosting, which is led into the re-evaporation tray on
the backside of the cabinet (see Fig.5). A re-evaporation hot gas pipe from the refrigeration
system, placed in the tray, re-evaporates the water. As a precaution in order to try avoiding
tray overflow during excessive load / many door openings, an electrical re-evaporation
heater, controlled by a float switch, is installed in this tray on R/GR and C products.
It is recommended to clean the re-evaporation tray and water trap when necessary -
at least once a year. Remember to disconnect the cabinet before cleaning.
Be careful not to damage the re-evaporation pipe (and the electrical re-evaporating
system) during cleaning.
Light - glass door
The light in the glass door, can be switched to work in two different ways.
Light constantly on (Lco) or light off when door closed (Ldo).
Push and hold
for 5 seconds to change between Lco and Ldo.
Power failure
In the event of a power failure, the control remembers the temperature setting and restarts
the product when power is restored. If the power failure persists for some time, the control
might revert to the factory setting.
Cleaning
Insufficient cleaning will cause that the product will not work at optimum performance, or
eventually it will be defective.
Before cleaning, the product should always be disconnected.
Do not flush the product with water, do not use water jet or steam hose
as this may cause short-circuits in the electrical system.
Cleansing agents containing chlorine or compounds of chlorine as well
as other corrosive means, are not to be used, as they might cause
corrosion to the cabinet and the refrigeration system.
The compressor compartment and in particular the condenser must be kept free
from dust and dirt. This is best done with a vacuum cleaner and a brush.
For the external maintenance and cleaning – Use a hot soapy damp cloth. After
cleaning rinse off with a moist cloth only containing water. Finalize the cleaning
by wiping the cabinet dry, using a dry cloth. Cabinets with stainless steel
exterior, should be treated with stainless steel polish at the end.
The product should be cleaned internally with a mild soap solution at suitable
intervals and checked thoroughly before it is put into operation again.