Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply
cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical
shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain
relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground
connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical
shock.
1. Disconnect power.
2.
Remove the hold-down screw and terminal block cover.
/
A. Neutral
ground
wire
B. External ground
conductor
screw
C. Cente/,
silver-colored
terminal
block
screw
D. Terminal
bMck
cover
and hokY-
dow[}
screw
3.
Install strain relief.
Style 1 : Power supply cord strain relief
Remove the screws from a W' (1.9 cm) UI_ listed strain relief (UI_ marking
on strain
relief).
Put the tabs of the two clamp
sections
into the hole below
the terminal
block
opening
so that one tab is pointing
up and the other is pointing
down,
and hold in
place. Tighten
strain relief screws enough
to hold the two clamp
sections together.
;................................
/
A
A. Strain
refief tab pointing
up
B. Hole
below
terminal
block
opening
C. Clamp
section
D. Strain
relief tab pointing
down