Strip 5" (12.7 cm) of outer covering
from end of cable, leaving
bare ground
wire at 5"
(12.7 cm). Cut 1 V2" (3.8 cm) from 3 remaining
wires. Strip insulation
back 1" (2.5 cm). Shape
ends of wires into a hook shape.
3.
Connect
ground
wire (green or bare) of direct wire cable to external
ground
conductor
screw. Tighten
screw.
When
connecting
to the terminal
block,
place the hooked
end of the wire under the screw of
the terminal
block (hook
facing right), squeeze
hooked
end together
and tighten
screw, as
shown.
2.
Remove center
silver-colored
terminal
block
screw.
Remove
neutral
ground
wire from external
ground
conductor
screw. Connect
neutral
ground
wire and place the hooked
end (hook facing right) of the neutral
wire (white or
center wire) of direct wire cable under the center screw of the terminal
block.
Squeeze
hooked
ends together.
Tighten
screw.
D
A. External
ground
conductor
screw
B. Ground
wire
(green
or bare)
of power
supply
cable
C. ¾"
( 1.9 cm) UL fisted strain
refief
D. Center
silver-colored
terminal
block
screw
E. Neutral
ground
wire
£ Neutral
wire
(white
or center
wire)
Place the hooked ends of the other direct
wire cable wires under the outer terminal
block
screws (hooks facing right). Squeeze
hooked
ends together.
Tighten
screws.
!! !!
JjJ
5.
Tighten
strain relief screw.
6.
Insert tab of terminal
block
cover into slot of dryer rear panel. Secure cover with
hold-
down screw.
7.
You have completed
your electrical
connection.
Now go to "Venting
Requirements."
[i
A. External
ground
conductor
screw
- Dotted
fine shows
position
of N_UTRA/_ . ground
wire .... before
being
moved
to
center
silver-colored
terminal
block
screw.
B. Center silver-colored
terminal
block
screw
C. Neutral
ground
wire
D. Neutral
wire (white
or center
wire)
E. 3/4" ( 1.9 cm)
UL listed strain
relief