No people may be located within the haz-
ard zone of the crane.
Do not leave the device hanging unattend-
ed on the crane.
6. Tip the container with the push handle.
Illustration H
7. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
8. Fit and lock the suction head.
Cleaning the liquid container
For the figures, please refer to the graphics
pages
Note
Bacterial contamination may occur through
the use of water-based cooling lubricants.
Wear suitable protective clothing when re-
moving deposits.
1. Empty the container.
2. Remove deposits in the container.
3. Dispose of the deposits in accordance
with the applicable regulations.
4. Remove chippings and deposits from
the support plates.
Illustration I
Removing the suction head
See graphics page for illustrations
1. Switch off the device and disconnect
from the power supply.
2. Open the lock for the suction head.
Illustration J
3. Remove the suction head and put to one
side.
Finishing operation
1. Switch off the device using the on/off
switch
2. Empty and clean the liquid container.
3. Remove the accessories and clean and
dry them as necessary.
Note
Empty the vacuum cleaner after every use.
Allow the vacuum cleaner to dry with the
container open.
Transport
CAUTION
Failure to observe the weight
Risk of injury and damage
16
Be aware of the weight of the device during
transport and storage.
1. When transporting in vehicles, secure
the device against slipping and tipping
over according to the applicable guide-
lines.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. Store the device indoors only.
Care and service
1. Rinse off the device and accessories at
regular intervals using a suitable liquid
and allow to dry.
2. To prevent contamination, do not leave
fluids in the device.
3. For longer breaks in operation, open the
cover to allow the residual moisture to
evaporate.
4. Replace the filter if damaged.
Replacing the filter
See graphics page for illustrations
Illustration K
1. Remove the suction head (see chapter
Removing the suction head).
2. Loosen the screws of the tensioning
rings.
3. Remove the small deflector plate.
4. Remove and replace the filter.
5. Insert the new filter.
Ensure that the filter is inserted correctly
during installation.
6. Fit the tensioning rings and screw them
on.
Troubleshooting guide
DANGER
Risk of injury
Danger of the device unintentionally start-
ing and danger of electric shock
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
English
Storage