FAULTS
Any faults detected are displayed by the Red LED (blinking);
The number of blinks (as shown in the table below) identifies the fault.
RED LED
Type of Fault
BATTERY
1 x Blink
DISCONNECTION
BATTERY VOLTAGE
2 x Blink
ERROR
3 x Blink
INTERNAL TEMP. HIGH
4 x Blink
MOSFET TEMP. HIGH
8 x Blink
MAINS VOLTAGE
9 x Blink
TIME OUT
11 x Blink
I MIN
GUARANTEE
The charger is guaranteed for 12 months from the date of installation.
-
The guarantee covers all proven defects in components, assembly, and construction.
-
Any incorrect installation or use of the machine NULLIFIES the guarantee.
-
Any unauthorised tampering NULLIFIES the guarantee.
-
In case of difficulties please contact the LOCAL DEALER.
-
SPE Elettronica Industriale di Poletti Sergio
Headquarter: Via di Mezzo Ponente, 383/B
40014 Crevalcore (Bologna) Italy
Description
Battery disconnected while the
battery charger was still charging
Voltage of the connected battery
incorrect or out of range.
High internal temperature, the battery
charger has gone into thermal
protection mode
High power components temperature,
the battery charger has gone into
thermal protection mode
Power supply voltage outside the
permitted range
Phase 1 safety timer expired, the
necessary conditions to continue
charging did not occur
Charging current below the minimum
level
pag. 11/26
Rev n° 1 del 11/06/2024
Solution
-Check the rated voltage of the
connected battery
-Check whether the battery voltage
is too high or low
Wait for the temperature to go
back to the correct value, charge
will automatically restart
Wait for the temperature to go
back to the correct value, charge
will automatically restart
-Check if the power supply voltage
is within the permitted range
-Check the state of the battery. -
Check that the charging current of
the battery charger is suited to the
battery capacity
-Check the state of the battery.