at the bottom in the display, while
the surface is indicated at the top.
The laser remains switched on.
Now, measure length B 2 of the
second wall. The individual
measuring value indicated at the
bottom of the display is added to
length B 1 and the sum of both
lengths is multiplied with the
stored length A. The total surface
value is indicated at the top in
the display.
In this manner, you can measure
any number of further lengths
B X , which are added and
multiplied with length A.
The condition for a correct
area/surface calculation is that
the first measured length (in the
example the room height A) is
identical for all partial surfaces.
To restart the multi-surface area
measurement, push button 11twice.
Continuous Measurement
(Tracking)(see figure J)
Use Min. / Max. measurement
mode for continuous
measurement function (tracking).
The continuous measurement
function (tracking) is used for the
transferring of measurements,
e.g., from construction plans. In
continuous measurement mode,
the rangefinder can be moved
relative to the target, whereby the
measured value is updated
approx.. every 0.5 seconds. As
an example, the user can move
from a wall to the required
distance, while the actual
distance can be read
continuously.
For continuous measurements,
select the Min. or Max.
measuring function. Move the
rangefinder until the required
distance value is indicated at the
bottom of the display.
Pushing the measurement button
10 interrupts the continuous
measurement.The current
measured value is indicated in
the bottom of display.
Repeated pushing of the
measuring button 10 starts the
measuring again.
The measuring automatically
switches off after 5 minutes. The
last measured value remains
indicated in the display. The
measuring can also be ended by
pushing button 5 or 11, which
changes the measuring mode.
Deleting Measured Values
Pushing on clear button 14
deletes the last individual
measuring value determined in
-18-