Télécharger Imprimer la page

PYD Electrobombas SP Serie Instructions D'utilisation Et Maintenance page 63

Publicité

Les langues disponibles

Les langues disponibles

INSTRUCTIONS D´UTILISATION ET MAINTENANCE
GROUPE DE POMPAGE SOLAIRE
4.2 Instructions de raccordement
Terminal
P+
ETH
P-
NC
1
2
3
COM2
TH
COM1
WL
WH
4.3 Instruction of water level sensors
Tank water level sensor: The tank water level sensor is used to detect the water level in the tank. Once
the tank is full, the sensor will stop the system. During installation, connect "COM2" at the bottom of
the tank, connect "TH" at the top of the tank. Once the water level is full, the system will stop in 8 s;
Once the tank is empty, the system will start working again in 5 minutes.
Well water level sensor: The well water level sensor is used to detect the water level in the well. Once
the well is empty, the sensor will stop the system. During installation, connect "COM1" and "WL" at the
bottom of the well, connect "WH" higher than "COM1". Once the well is empty, the system will stop in
10 s; Once the water level is higher than "WH" level, the system will start working again in 30 minutes.
www.proindecsa.com / proindecsa@proindecsa.com
Instruction
Panneau solaire positif
Masse
Panneau solaire négatif
VIDE (NON UTILISÉ)
Connexion au moteur de la pompe Câble 1
Connexion au moteur de la pompe 2.
Connexion au moteur de la pompe 3.
RÉSERVOIR COMMUN (capteur de niveau d'eau)
RÉSERVOIR PLEIN (capteur de niveau d'eau)
Puits commun (capteur de niveau d'eau)
Puits vide (capteur de niveau d'eau)
Niveau de récupération de l'eau de puits
(capteur de niveau d'eau)
63

Publicité

loading

Ce manuel est également adapté pour:

Th serieSt serie