OPERATING AND MAINTENANCE MANUAL
SOLAR PUMPING GRUOP
1. SECURITY
1.1 Before switching on
Make sure the terminal wire connections are correct, "P +", "P-" are for panel connection, "1", "2", "3"
are for pump connection, incorrect connection will cause damage to the controller.
The series voltage of the panels is not allowed to exceed the open circuit voltage of the controller.
The control module and the motor must be of the same power.
Secure insulation and aluminium board during installation.
1.2 In operation:
When the system is running, it is not allowed to disconnect the motor and the controller, otherwise
damage may occur.
When the system is operating, do not tamper with or examine parts of the circuit board or the
signal..
Do not replace any internal parts damaged by overvoltage or overcurrent.
Examine or repair only by authorised personnel.
2. TECHNICAL DATA
Model
Specification
Rated voltage
Rated current
Maximum working current
Minimum working current
Open circuit voltage input
Open circuit voltage max.
Open circuit voltage min.
Maximum power
Overload
Current
Over current
www.proindecsa.com / proindecsa@proindecsa.com
150V
150VDC
200VDC
10A
12A
1.3A
>170VDC
>272VDC
250VDC
350VDC
90VDC
150VDC
1,5KW
15 ± 0,5A
15 ± 0,5A
32 ± 0,5A
32 ± 0,5A
38
220V
300V
300VDC
10A
12A
1.3A
>340VDC
450VDC
220VDC
2,2KW
15 ± 0,5A
32 ± 0,5A
10A
12A
1.3A
3KW