OPERATING AND MAINTENANCE MANUAL
SOLAR PUMPING GROUP
7. MAINTENANCE
7.1. Regular maintenance project
The output voltage of each panel is in the normal range..
The tightness of the terminal screws.
Check if there is any liquid / dust / scrap etc... in the controller.
Check if there is any noise or vibration from the pump when the system is switched on..
7.2. Attention during maintenance.
Disconnect input power to the controller before maintenance..
Disassembled metal spare parts cannot be placed in the controller, which will lead to an open
circuit of the controller..
Keep the controller clean after maintenance, prevent dust or liquid from entering the controller.
8. ERROR CODE AND MEANING
E001: Overcurrent protection
E002: Voltage protection
E003: Current + Voltage Protection
E004: Tank Protection
E005: Overcurrent + Tank Protection
E006: Voltage + Tank Protection
E007: Current + Voltage + Tank Protection
E008: Under well level protection
E009: Low level + Overcurrent Protection
E010: Low level + Voltage protection
E011: Low level + Current + Voltage Protection
E012: Tank + Low level + Low level protection
E013: Tank + Low level + Current protection E014: Tank + Low level + Current protection
E014: Tank + Low Level + Voltage Protection
E015: Tank + Low Level + Current + Voltage Protection E015: Tank + Low Level + Current + Voltage
Protection
E016: Data error
E032: Verification error
E064: Communication failure (try disconnecting everything and restarting)
E064: Communication failure (try disconnecting everything and restarting)
E065: Communication failure (try disconnecting everything and restarting)