Troubleshooting
Problem
Possible Cause
When using the
Incorrect positioning of the device or
IsoRocker® on a
too high an intensity level.
hard floor it makes a
tapping noise.
My legs are aching
You may have the intensity on too
after treatment.
high a setting and your muscles are
being overworked.
I have placed my feet
TENS is only available through the
on the device but
Electrode Pads.
am unable to see the
TENS symbol on the
control panel
When using the Body
The level of stimulation you are
Pads, the stimulation
using may be too high or you may
feels uncomfortable.
have broken skin.
I am unsure of which
therapy mode I am
using when using the
Body Pads.
I suddenly can't feel
You may have pressed the other
stimulation when
stimulation mode button by
using the Body Pads.
accident.
You may have accidentally
paused the stimulation session by
disconnecting
a pad.
For more information including Frequently Asked Questions,
please visit www.revitive.com
26
7376_IFU01_19000014.indd 26-27
7376_IFU01_19000014.indd 26-27
Solution
Adjust the positioning of the device or lower
the intensity level to reduce the device tapping.
Alternatively use a floor mat under the device to
cushion the sound.
Leave adequate time after each treatment to allow
the muscles to recover (just like after vigorous
exercise!). On your next session start on a lower
setting (where you can feel the mild electrical
stimulation and it is comfortable) and reduce the
duration until your muscles have acclimatized to
the stimulation.
Decrease the stimulation level using the (–) inten-
sity control on the device or remote control. You
may need to discontinue use until skin has healed.
Look at the display on the device. If the Body Pads
are in EMS mode, you will see the EMS symbol. If
the Body Pads are in TENS mode, you will see the
TENS symbol.
Pressing the opposite stimulation mode button
(i.e. pressing the TENS button when already in
EMS mode or vice versa), will reset the timer back
to 30 minutes. The intensity will also be reset to
zero. The mode, intensity and time settings will
need to be re-made.
Reconnect the pads to your body or re-connect the
cord and press the (+) to resume your session.
Technical Specifications
Name of product
Model
Frequency
Output current
Weight
Dimensions
Power consumption
AC adaptor
Power source
Input (adaptor used)
Output
Battery
Battery Life
Applied parts
Parts of Revitive that in normal use come into
physical contact with the user.
Durable Period (Service Life) of Device and Remote
Control
The Remote Control replicates the controls found on the device
Operating Frequencies
Operating Range Distance
EN
Revitive Medic
5573AQ
EMS: 20Hz – 53Hz
TENS: 80Hz - 130Hz
EMS: Max 15mA
TENS: Max 19mA
1.4 Kg
360mm (Ø) x 76.5mm (D)
5W
CE Approved
100-240V
AC (
), 50/60Hz, 0.18A
5V (
) DC
,1.0A
Lithium Ion, 1200mAh, 3.7V
500 charge cycles
Electrode Body Pads - 5cm x 5cm = 25cm
2
SoftTouch Pads (Foot-Pads) - 253.69cm
2
4 Years
38 KHz
0 to 25m at horizontal
0 to 18m at +/- 30 degree angle
from the horizontal.
27