SAFETY INSTRUCTIONS
Height of the back of the appliance
Width of the front of the appliance
Width of the back of the appliance
Depth of the appliance
Built in depth of the appliance
Depth with open door
Ventilation opening minimum size. Opening placed
on the bottom rear side
Mains supply cable length. Cable is placed in the
right corner of the back side
Mounting screws
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
• All electrical connections should be made by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the rating plate are compatible with the electrical ratings
of the mains power supply.
• Always use a correctly installed shockproof socket.
• Do not use multi-plug adapters and extension cables.
• Make sure not to cause damage to the mains plug and to the mains cable. Should the mains
cable need to be replaced, this must be carried out by our Authorised Service Centre.
• Do not let mains cables touch or come near the appliance door or the niche below the
appliance, especially when it operates or the door is hot.
• The shock protection of live and insulated parts must be fastened in such a way that it
cannot be removed without tools.
• Connect the mains plug to the mains socket only at the end of the installation. Make sure
that there is access to the mains plug after the installation.
• If the mains socket is loose, do not connect the mains plug.
• Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.
• Use only correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed
from the holder), earth leakage trips and contactors.
• The electrical installation must have an isolation device which lets you disconnect the
appliance from the mains at all poles. The isolation device must have a contact opening
width of minimum 3 mm.
• Fully close the appliance door before you connect the mains plug to the mains socket.
6/196
571 mm
595 mm
559 mm
569 mm
548 mm
1022 mm
560x20 mm
1500 mm
4x25 mm