Once switched on, the battery will be visible with the name 'TLB100xxxxx' ('xxxxx' representing the serial number
of the battery) in the Bluetooth menu of the Dometic Energy app.
9 Battery configuration
Selecting the desired BUS
The battery supports both the native N-BUS protocol and the CI-BUS protocol that is shared with other manufactur-
ers.
N-BUS setup (default)
To select the N-BUS deactivate the DIP switch 1 (A).
To select the CI-BUS activate the DIP switch 1 (B).
NOTE
• When CI-BUS protocol is active the N-BUS will not be detected.
• CI-BUS is suitable for up to 3 batteries connected in parallel. For configurations with more than 3
batteries connected in parallel, use N-BUS.
Setting the battery as MASTER or SLAVE
N-BUS setup
Battery set as Master (default).
Download the NDS | DOMETIC app.
CI-BUS setup
CI-BUS setup
Battery set as Master.
EN