Unpacking
Please unpack the device carefully.
In the case of any damage a detailed report must be sent
immediately (post, rail or forwarder)
Delivery scope
Vacuum controller VC 10 lite/pro
Universal plug-in power
supply unit
USB A - micro B cable
Use
Together with the accessories recommended by , the VC 10 lite/
pro vacuum controller is suitable for the controlled evacuation of
air (gas) from laboratory devices and equipment (e.g. rotary eva-
porator or laboratory reactors, and also for classical separation or
filtration or drying tasks in the laboratory) in conjunction with a
suitable vacuum source (e.g. MVP 10 basic / VACSTAR).
The VACSTAR can be operated automatically with the VC 10 pro
Area of use
Indoor environments similar to that a laboratory of research,
teaching, trade or industry area.
The safety of the user cannot be guaranteed:
- If the device is operated with accessories that are not supplied
or recommended by the manufacturer;
- If the device is operated improperly or contrary to the
manufacturer's specifications;
- If the device or the printed circuit board are modified by the
third parties.
In addition to a high-resolution Al
lite/pro vacuum controller has an integrated vacuum valve and a
venting valve. As a result, the VC 10 lite/pro vacuum controller can
be used without any additional peripheral devices.
The VC 10 pro provides two basic modes of operation:
Two-position control and analogue speed control.
The change between the two modes is performed automatically
by plugging or unplugging the connector cable at the "VACSTAR"
interface. Depending on the selection made, some submenu items
may not be available (greyed out on the display).
Unpacking
Fig. 2
Fig. 3
Intended use
Useful information
O
pressure sensor, the VC 10
2
3
Vacuum hose 1 m
Y connector
Operating instructions
Warranty card
vacuum controller.
Therefore, it can be used for automatic boiling point recognition,
programmed pressure-time curves or programs from the solvent
library, for example.
Mode of operation: Stand device
The device must not be used for:
WARNING
- vacuation of biological biotopes,
- evacuation of explosive, corro-
sive or gas volumes,
- throughput/use of fluids!
With two-position control, parameters from the solvent library can
be applied or target values specified in manual mode.
With analogue speed control, an automatic mode as well as the
setting of the percentage pump speed can also be preset.
Space requirement: To connect all peripheral devices you will need
approximately WxDxH 150 x 200 x 155 mm³ space for the device
with connected plugs.
Fig. 4
Fig. 5
31