Télécharger Imprimer la page

Telecom Behnke 43-9607B Manuel D'instructions page 37

Publicité

Les langues disponibles

Les langues disponibles

Mounting a sabotage contact
Top
Lid electronics box
Holes for
Sabotage contact
20
Dimensions in mm
www.behnke-online.com
Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
Sabotage contact
Nuts
Door Secure Adapter
Behnke in-wall housing series 20 / 40 / 50
Mounting material supplied:
2 x spacer roller 5 mm
2 x Phillips screw M2.5 x 10 mm V2A
2 x nut M2.5 V2A
1 x sabotage contact
1. First, screw the sabotage contact of the Door
Secure Adapter and the
cover of the basic electronics using the
Phillips screws M 2.5 x 10 mm provided. To
ensure the required distance between the
cover of the electronics box and the sabo-
tage contact, mount the two spacer rollers
(5 mm) between the sabotage contact and
the top of the housing cover (see drawing).
2. Now push the two M 2.5 x 10 mm Phillips
screws
through the two holes in the sabotage
contact.
3. Place the two spacer rollers (5 mm) on the
two Phillips screws.
4. Insert the sabotage contact with the two
screws
through the two holes in the cover.
5. Secure the sabotage contact with the two
M 2.5 nuts.
6. Now please perform the function test of the
sabotage contact using a multimeter. When
the sabotage contact is actuated by inserting
it into the in-wall housing, the switching con-
tact is closed. Do not connect the sabotage
contact to the Door Secure Adapter. When
the button is closed, a resistance value of
approx. 5.1 kΩ should now be measured at
the terminals. Wire the sabotage contact to
the Door Secure Adapter in the building after
performing a test measurement.
GB
37