Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
GB
Secure Ethernet Adapter
e) Behnke surface-mounted housing 20/40/50
with basic electronics 20-0001B-IP
30
ø 3 mm
ø 3 mm
15
35
Sabotage contact
1. Be sure to remove the module housing cover
of your 20-0001B-IP basic electronics from
the basic electronics and drill the two holes
(see sketch on the left).
2. Screw the two M 2.5 x 18 mm spacer bolts
inside/inside to the module housing cover
using the two M 2.5 x 6 mm Phillips screws.
3. Screw the sabotage contact to the two
M 2.5 x 18 mm spacer bolts using the two
M 2.5 x 6 mm Phillips screws.
Now please perform a function test of the
sabotage contact using a multimeter. When the
sabotage contact is actuated by inserting it into
the in-wall housing, the switching contact is
closed. Do not connect the sabotage contact to
the Secure Ethernet Adapter. When the button
is in closed position, a resistance value of
approx. 5.1 kΩ should now be measured at the
connection line to the Secure Ethernet Adapter.
Wire the connection line of the sabotage
contact to the Secure Ethernet Adapter in the
building after performing a test measurement.
Mounting material supplied:
▸ 2 x stud bolt M 2.5 x 18 mm inside/inside
▸ 4 x Phillips screw M 2.5 x 6 mm V2A
▸ 1 x sabotage contact
www.behnke-online.com