d) Behnke surface-mounted housing 20/40/50
with basic electronics 20-0001A-IP, 20-0014A-
IP
and 20-0043A-IP
1. First detach the module housing base
without hole and spacer from the electronics
box.
2. Screw on the module housing base with hole
and spacer and screw it to the intercom base
housing.
3. Screw the sabotage contact to the 18 mm
spacer using the M 2.5 x 6 mm Phillips
screws
4. Now please perform the function test of the
sabotage contact using a multimeter. When
the sabotage contact is actuated by inserting
it into the surface-mounted housing, the
switching contact is closed. Do not connect
the sabotage contact to the Secure Ethernet
Adapter. When the button is closed, a
resistance value of approx. 5.1 kΩ should
now be measured at the terminals. Wire the
sabotage contact to the Secure Ethernet
Adapter in the building after performing a
test measurement.
Mounting material supplied:
▸ 1 x bracket for sabotage contact incl.
2 stud bolts M 2.5 x 18 mm inside/outside
▸ 2 x Phillips screw M 2.5 x 6 mm V2A
▸ Sabotage contact
www.behnke-online.com
Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
Secure Ethernet Adapter
Top
Module housing base with preparation
for sabotage contact