Pin assignment
Input 48 V / min. 350 mA (e.g. 20-9599)
Connection
8
9
Door opener of the sabotage loop
Connection
1, 2
3, 4
6, 7
Network
Connection
11 - 13
14 - 16
Operating elements
Connection
5
19
1.4. Specifications
Current consumption: max. 350 mA at 48 V=
Operating voltage: POE Class 0 alternatively
48 V= / min. 350 mA
www.behnke-online.com
Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
Secure Ethernet Adapter
Signal name
-48 V/min. 350 mA = (alternatively POE)
+48V/ min. 350 mA = (alternatively POE)
Signal name
Door opener circuit / signalling device
(normally closed contact)
Door opener circuit / signalling device
(normally closed contact)
Sabotage loop (5.1 kΩ measurable when sabo-
tage contact is actuated)
Signal name
LAN output, RJ-45 socket (to end device / door
intercom station)
LAN input, RJ-45 socket (to PoE switch / POE
injector (PoE according to IEEE 802.3af class0))
Signal name
Reset button
Operating LED
Dimensions (H x W x D): 90 x 53 x 60 mm (3TE)
Temperature range: 0° C to 85° C
CE mark: EN55022
Relay: 30V, 2A; AC and DC
GB