Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
GB
Secure Ethernet Adapter
1.3. Commissioning
Wiring diagram 5-IP / 10-IP
The following diagram shows a typical installa-
tion with an external door station (5-IP/10-IP) in
connection with a door opener circuit.
Outdoor
5.1*
*
Door opener not included in the scope of delivery.
After correct assembly, check the resistance
value of 5.1 kΩ through measurement. After-
wards, relay 2 must be configured accordingly
in the web frontend of the SIP intercom station.
See the "Help function" in the web frontend of
the 5-IP/10-IP series SIP intercom station. This
function is only guaranteed if the 5-IP/10-IP
32
Secured interior
to the door
intercom station
5.1 kΩ resistance
*
(included in the scope
of delivery)
Connect in parallel to
normally open relay 2.
*
DO
Please note: SIP intercom station
series 5/10 must have firmware version
R238.55.201809101313 BT 3 Build 216.
to the
switch
LAN with PoE
10 11 12 13 14 15 16 17
19
Reset button
to the sabotage contact
at the door intercom station
1 2 3 4 5
6 7 8 9
+
Alternative power
supply instead of POE class 0
48 V / min. 350 mA =
(e.g. 20-9599)
Pot. free normally closed
contact e.g. for a signaling
device or additional door
opener control unit
Power supply for door opener
(on-site)
series device is installed in a Behnke in-wall
housing or surface-mounted housing that
matches the 5-IP/10-IP series or in a Behnke
pedestal that matches the 5-IP series. In the
case of cavity wall mounting, the customer must
ensure that the sabatoge contact of the Series
5-IP/10-IP device has a defined contact point.
Operating LED
www.behnke-online.com