Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
GB
Secure Ethernet Adapter
c) Behnke in-wall housing series 20/40/50 with
basic electronics 20-0014B-IP
Module housing base with preparation
for sabotage contact
28
Top
1. First detach the module housing base with-
out hole and spacer from the intercom base
housing.
Screw on the module housing base with hole
and spacer and screw it to the intercom base
housing.
2. Extend the two 18 mm spacers on the
module housing base to 28 mm using the
two stud bolts inside/outside M 2.5 x 10 mm.
3. Screw the sabotage contact to the 28 mm
spacer using the M 2.5 x 6 mm Phillips
screws.
4. Now please perform the function test of the
sabotage contact using a multimeter. When
the sabotage contact is actuated by inserting
it into the surface-mounted housing, the
switching contact is closed. Do not connect
the sabotage contact to the Secure Ethernet
Adapter. When the button is closed, a
resistance value of approx. 5.1 kΩ should
now be measured at the terminals. Wire the
sabotage contact to the Secure Ethernet
Adapter in the building after performing a
test measurement.
Mounting material supplied:
▸ 1 x bracket for sabotage contact incl.
2 stud bolts M 2.5 x 18 mm inside/outside
▸ 2 stud bolts M 2.5 x 10 mm inside/outside
▸ 2 x Phillips screw M 2.5 x 6 mm V2A
▸ Sabotage contact