1.2. Commissioning
Wiring diagram series 20 / 40 / 50
The following diagram shows a typical instal-
lation with an external IP door station of the
above mentioned device series in connection
with a door opener which is switched via relay 1
of the door intercom station.
Outdoor
Behnke SIP
intercom
station
Behnke sabotage
contact (included in
the scope of deliv-
ery), position to be
observed depending
on the intercom station
type, described in the
further course of these
instructions.
Relay 1
IP basic electronics
*
If relay 2 of the SIP intercom station is used for door opening, the IP basic electronics must be configured accordingly.
See also Web frontend (IP intercom station)
**
Door opener not included in the scope of delivery.
www.behnke-online.com
Instructions Secure Ethernet Adapter (43-9607B) / Secure Door Adapter (43-9606)
Secured interior
to the door
LAN via PoE
intercom station
*
**
DO
Secure Ethernet Adapter
Only functions properly when installed in
Behnke in-wall housings or surface-mounted
housings or in Behnke stainless steel pedestals
(with suitable accessories).
to the
switch
LAN with PoE
10 11 12 13 14 15 16 17
19
Reset button
to the sabotage contact
at the door intercom station
1 2 3 4 5
6 7 8 9
+
Alternative power
supply instead of POE class 0
48 V / min. 350 mA =
(e.g. 20-9599)
Pot. free normally closed
contact e.g. for a signaling
device or additional door
opener control unit
Power supply for door opener
(on-site)
Operating LED
GB
25