BSPU 800/19 - BSPU 900/24 - BSPU 1300/24
PROBLEM
Motor will not start
Pump will not suck
Pump connects
with very low
water intake
Insufficient rate
of flow
The thermal cut-
out switch cuts
off the pump
PROBLÈME
Le moteur ne
démarre pas
La pompe
n'aspire pas
Débit insuffisant
Le relais thermique
désactive la pompe
TROUBLESHOOTING
CAUSES
No mains voltage
f
Pump impeller jammed
f
Thermostat detached
f
Suction valve not in water
f
Pump chamber with no water
f
Air in suction pipe
f
Suction valve not airtight
f
Suction rose (suction valve) clogged
f
Max. suction lift exceeded
f
Pressure of air cushion in the
f
delivery tank too low.
Suction height too high.
f
Dirty suction rose.
f
Water level falls quickly.
f
Pump flow rate reduced by foreign
f
bodies.
Motor overloaded. Friction too
f
great due to foreign bodies
RÉSOLUTION DES PROBLÈMES
CAUSES
Absence alimentation électrique
f
Couronne pompe bloquée
f
Thermostat débranché
f
Le clapet d'aspiration n'est pas
f
dans l'eau
Chambre pompe sans eau
f
Air dans le tuyau d'aspiration
f
Clapet d'aspiration non étanche
f
Crépine obstruée
f
Dépassement de la hauteur max.
f
d'aspiration
Hauteur d'aspirat. trop élevée
f
Crépine encrassée
f
Le niveau de l'eau baisse rapid.
f
Débit de la pompe réduit par des
f
corps étrangers
Moteur surchargé.
f
Frottement trop fort dû à des
corps étrangers.
ENGLISH
REMEDIES
Check voltage
f
Dismantle the pump and clean
f
Put the suction valve into water (min.
f
30cm.)
Pour water into the suction union
f
Check the seal of the suct. pipe.
f
Clean the suction valve.
f
Clean the suction rose.
f
Check the suction height
f
Increase the pressure of the air cushion in
f
the filling valve (1.5 bar)
Check suction height.
f
Clean the suction rose.
f
Set the suct. valve lower down.
f
Clean the pump and replace the worn parts.
f
Eliminate the foreign bodies. Wait for the
f
thermal cut-out switch to trigger again
(approx. 20 mins.).
FRANÇAIS
REMEDIES
Vérifier l'alimentation
f
Démonter la partie hydraulique et contrôler
f
si la couronne peut tourner librement, puis
remonter soigneusement
Plonger le clapet d'aspiration dans l'eau
f
(30cm min.)
Verser de l'eau dans le raccord d'aspiration
f
Vérifier l'étanchéité du tuyau d'aspiration
f
Nettoyer le clapet d'aspiration
f
Nettoyer la crépine
f
Contrôler la hauteur d'aspiration
f
Vérifier la hauteur d'aspiration
f
Nettoyer la crépine
f
Abaisser le clapet d'aspiration
f
Nettoyer la pompe et remplacer les pièces
f
usées
Eliminer les corps étrangers.
f
Attendre que le relais thermique se
déclenche à nouveau (20 min.)
53