Télécharger Imprimer la page

FILL-RITE NX25-DDC Serie Manuel D'installation Et D'utilisation page 8

Publicité

Les langues disponibles

Les langues disponibles

|
Operational Safety
DANGER
DO NOT use pump in enclosed areas when pumping hazardous or explosive fluids. Pumping area should be well ventilated. Concentrated vapors
in an enclosed area are noxious and highly explosive!
WARNING
NEVER disconnect the power cable from the pump while pump is switched on or connected to a power source. ALWAYS switch the pump off
and disconnect all the clamps from the power source PRIOR to disconnecting the power cable from the pump. Electrical shorts, sparks, or
unexpected start up can occur.
WARNING
Use caution when operating the pump. The hoses and electrical power cable can be a trip hazard; caution should be exercised while moving
around the hoses and power cable connected to avoid tripping or entanglement.
WARNING
Pump assembly can become hot with extended use. Use caution if you have to touch the pump after extended periods of use.
CAUTION
Always keep the nozzle in contact with the container being filled during the filling process to minimize the possibility of static electricity build up.
Operating Instructions
CAUTION
Always keep the nozzle in contact with the container being filled during the filling process to minimize the possibility of static electricity build up.
1.
If so equipped, reset Meter to "0" (do not reset while in use as this can cause damage to the meter).
2.
Remove dispensing nozzle from nozzle boot.
3.
Move the switch lever to the "ON" (raised) position to start the motor (Figure 5). The pump should start and settle into a slow idle.
4.
Insert the dispensing nozzle into the container to be filled.
5.
Operate the nozzle to dispense fluid; release nozzle when the desired amount of fluid has been dispensed.
6.
Move switch lever to the "OFF" (lowered) position (Figure 6) to stop the motor.
7.
Remove the dispensing nozzle from the container being filled and store it in the nozzle boot.
NOTICE
The motor has power at all times when connected to a power source. The switch does not apply or interupt power to the motor. High voltage may
still be present inside the pump after power is removed.
fillrite.com
NX25-DDC SERIES DC FUEL TRANSFER PUMPS
Figure 5
Switch "ON"
INSTALLATION AND OPERATION MANUAL
Figure 6
Switch "OFF"
8

Publicité

loading