Set the flame to the minimum level
■ Do not disassemble the valve shaft: in the event of a malfunction, replace the
entire valve.
■ Before putting the burners back on the cooktop, make sure that the injector is
not blocked.
■ A complete operational test and test for possible leaks must be performed after
the gas conversion (such as the soapy water test or with a gas detector).
■ After completing the conversion, a qualified technician or installer must mark "V"
on the correct gas category corresponding to the setting on the Material Safety
Data Sheet. Remove the previous "V" mark.
Turn the taps to the minimum level
Remove the faucet knob and place a small screwdriver in the
control
center of the faucet shaft.
The correct setting is obtained when the flame has a length
Tap
of 3 to 4 mm.
Seal ring
For butane / propane gas, the adjusting screw must be
firmly tightened.
Replace the adjustment knob.
Make sure the flame does not go out quickly from maximum
flow to minimum flow. If this is the case, remove the knob
and make further adjustments to the gas flow and test again
after the adjustment has been made.
4. Repeat this procedure for each of the gas faucets.
60