Automatic ignition with safety device
The apparatus is equipped with a safety device in case of non-ignition of the flame on
each burner, which is designed to stop the diffusion of the gas towards the burner head
if the flame is not lit.
To light the burner:
o Press the burner control knob you want to turn on and turn it counterclockwise to the
maximum position.
o If you hold down the control button, the automatic burner ignition will work.
o You must hold the control button down for 15 seconds once the burner flame is on.
If after 15 seconds the burner has not been lit, stop operating the device and open the
compartment door and / or wait at least 1 minute before attempting to light the burner
again.
o After this 15 second interval, to regulate the flame, you must continue turning the
control knob counterclockwise until the flame is at an appropriate level. The operating
position must be at a position between the maximum and minimum position.
o To turn off the burner, turn the control knob fully clockwise until the gas is turned off.
o In the event of a power failure, the burners can be lit using a match.