Télécharger Imprimer la page

GiBiDi AS06321 Instructions Pour L'installation page 18

Publicité

Les langues disponibles
  • FR

Les langues disponibles

18
UK
MOTOR 1 OPENING
DIP1_4
LIMIT SWITCH
MOTOR 1 CLOSING
DIP1_5
LIMIT SWITCH
MOTOR 2 OPENING
DIP1_6
LIMIT SWITCH
MOTOR 2 CLOSING
DIP1_7
LIMIT SWITCH
DIP1_8
PHOTOCELL
TERMINALS 7-8
DIP1_9
FUNCTIONING
HYDRAULIC LOCK
DIP1_10
UPKEEP
9 - DIP SWITCH DIP2
The settings are stored during the rest phase (gate closed
The default settings are highlighted in the boxes with grey background.
DIP
Function
TERMINAL 23
DIP2_1
FUNCTIONING
TERMINAL M4
DIP2_2
FUNCTIONING
DIP2_3
UNUSED
POSITIONAL TIME
DIP2_4
RECOVERY
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the limit switch input
Enables the limit switch input
OFF
ON
Disables the photocell input
OFF
Enables the photocell input
The outputs 7-8 of the terminal board are used to control a FLASHING LIGHT
ON
equipped with its own flashing circuit.
The outputs 7-8 of the terminal board are used to control a COURTESY LIGHT
OFF
that remains active for 2 minutes after the motor movement.
For HYDRAULIC motors only.
If the gate has not performed any operation in the last 5 hours, a 2-second
ON
closing pulse is given.
THE STOP KEY DISABLES THE FUNCTION.
OFF
HYDRAULIC LOCK UPKEEP deactivated.
Description
Status
The STOP input (23) functions as EDGE and when activated, will invert the
ON
motion for 2 seconds in order to free the obstacle.
See also jumper SW15.
The STOP input (23) functions as STOP and when activated, will stop the
OFF
motion. See also jumper SW15.
ON
Terminal M4 operates as WARNING LIGHT.
Terminal M4 operates as FLASHING LIGHT.
In this mode, the terminals 28-29 can be used to connect a FLASHING LIGHT
OFF
without a flashing circuit.
Keep this OFF, do not change.
OFF
Extended positional time recovery:
ON
- Ideal for AGO motors with run time learning done
- Ideal for TOP EVO motors with hydraulic slowdown
OFF
Normal positional time recovery.
In the case of a system with only one
motor and using the limit switches,
the DIP switches 4, 5, 6 and 7 are
to be set to OFF; while if using only
one type of limit switch (e.g. FCAM1
and/or FCCM1), enable only the
corresponding DIP switch (set to OFF).
).
F4

Publicité

loading

Ce manuel est également adapté pour:

F4