16
UK
6 - PROTECTION FUSES
Position
Value
F1
6.3A
F2
160mA
7 - WARNING LEDs
LED
Colour
L1
RED
L2
RED
L3
RED
L4
RED
L5
RED
L6
GREEN
L8
GREEN
L9
BLUE
L10
RED
Type
Description
Protects the circuit board and the motors.
T
T
Protects the circuit board and the accessories.
Signal
Description
Always on. Turns off when the CLOSING LIMIT SWITCH of motor 2 is reached.
FCCM2
FCAM2
Always on. Turns off when the OPENING LIMIT SWITCH of motor 2 is reached.
Always on. Turns off when the CLOSING LIMIT SWITCH of motor 1 is reached.
FCCM1
FCAM1
Always on. Turns off when the OPENING LIMIT SWITCH of motor 1 is reached.
Always on. Turns off when the photocell is broken/interrupted.
PHOTO
Comes on when the START command is activated and goes off when released.
START
PED
Comes on when the PED. start command is activated and goes off when released.
0.6s ON 0.6s OFF
CONTINUOUS
30s ON
0.2s ON-2s OFF
CONTINUOUS
MEMO
0.2s ON - 0.2s OFF
0.2s ON - 1s OFF
CONTINUOUS
0.3s ON - 0.3s OFF
0.3s ON - 0.3s OFF
0.3s ON - 1s OFF
X4
3s ON-1s OFF
X3
Always on. It turns off after STOP/EDGE INPUT intervention.
SAF. / STOP
The control unit is blocked waiting to do the learning cycle.
It is necessary to do the learning cycle.
The control unit is in pre-learning phase after the activation of memo
button.
At rest and during the learning, the control unit is set for the operation
with 1 motor.
At rest and during the learning, the control unit is set for the operation
with 2 motors.
Learning aborted. Check photo-stop-edge-ped inputs.
Signalling made also on WARNING and FLASHING LIGHT.
Learning correctly made.
Signalling made also on WARNING and FLASHING LIGHT.
F4