If the system is placed on the floor, do not position it where it may be stepped on when getting out of bed.
CAUTION
The circular data port connector, located on the back of the IntelliPAP, is used to attach accessories to the device.
The connector must only be used with accessories approved for use by DeVilbiss. Do not attempt to attach any other
device to this connector, as it may damage the CPAP or the accessory device.
Never rinse or place the device in water. Never allow liquids to get into or around any of the ports, switches or air
filter. Doing so will result in device damage. If this occurs, discontinue use and remove the power cord from the
power source. Allow the device to completely dry before use.
Do not place the IntelliPAP where it can be knocked onto the floor, or where the power cord may create a tripping
hazard.
Only the DeVilbiss DV5 series Heated Humidifier system is recommended for use with the IntelliPAP. Other
humidifier systems may prevent the device from detecting snoring and may cause inappropriate pressure levels in
the mask.
Empty and dry humidifier water chamber before transporting.
INTRODUCTION
Intended Use
The DeVilbiss IntelliPAP Model DV57 Series AutoBilevel CPAP is intended for use in treating OSA in spontaneously
breathing patients 30 Kg (66 lbs) and above by means of application of positive air pressure. The device is to be used in
home and clinical environments.
Indications For Use (Optional Heated Humidifier)
Use on the advice and prescription of a licensed physician to help relieve the symptoms of dryness of the throat, nasal
passages and the mouth, which are common with positive airway pressure therapy. This is especially true in dry climates
and during the cold season when humidity in the air is typically lower than at other times.
Essential Performance:
Sleep Apnea Breathing Therapy Equipment is considered not to have essential performance.
Contraindications
Do not use IntelliPAP system if your upper airway has been bypassed. Positive airway pressure therapy may be
contraindicated in some patients with the following pre-existing conditions:
severe bullous lung disease
pneumothorax or pneumomediastinum
pathologically low blood pressure, particularly if associated with intravascular volume depletion
dehydration
cerebrospinal fluid leak, recent cranial surgery or trauma
NOTE–Symptoms of dryness of the throat, nasal passages and the mouth are common with positive airway pressure
therapy. The IntelliPAP features an optional humidifier system to help minimize these effects.
AutoBilevel Operating Diagram
AutoBilevel is typically used for OSA patients with higher prescribed pressures.
A-DV57
EN - 5