PUTTING INTO
OPERATION
If the cabinet has been sharply tilted while
being sited or for mounting of accessories, it
must be left to stand for at least three hours
before being started to allow the lubricating
oil to settle in the compressor. Failure to do so can cause total
destruction of the compressor refrigerating system.
Check that the voltage on the identification plate is the same
as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE
REFRIGERATOR WILL HAVE TO BE CONNECTED
IS TO BE PROTECTED BY A VERY SENSITIVE
DIFFERENTIAL SWITCH (Rc=16A,Dc=30mA); IT IS
ALSO TO BE LINKED TO THE GENERAL EARTHING
PLANT.
Follow the manufacturer's instructions to install the unit, using
qualified personnel and complying with the electrical regulations
for the specific country. Incorrect installation may cause injury
and damage; the manufacturer is not liable for this.
The manufacturer disclaims all responsability for any damage
to people or things due to incorrect observance of this rule.
Earthing is necessary and compulsory by law. Absolutely never use reduction units, patch cords,
adapters or multiple socket outlets to connect the counter. DIRECTLY connect the equipment to
the mains.
The cable should be fully extended and located where it is unilikely to be struck, caught or
stepped on, away from water and the other liquids and heat sources and must not be damaged.
In case of breakage of the power cable of the cabinet, it must be replaced by the manufacturer or by
instruction it change of it. The plug must still be accessible even after installing the unit.
PERIODIC MAINTENANCE
WARNING! ANY WORK CARRIED OUT ON THE APPLIANCE BY THE
USER STRICTLY REQUIRES THE POWER PLUG BEING DISCONNECTED
FROM THE MAINS SOCKET.
Inspect the power cable to see if it is damaged.
If the power cable is damaged, do not use the appliance and try to repair it: it must be replaced by
the manufacturer or its customer service department or by a similarly qualified person, in order
to prevent any risks.
No protection (grill or guard) should be removed by unqualified personnel and strictly avoid
operating the appliance with these protections removed.
SEASONAL USE
When the unit is not used for a long time, please take note of the following procedures:
- unplug the unit;
- clean and dry the tank well;
- leave the tank open to avoid possible formation of bad odours;
- cover the unit with a curtain, place it in a dry room and sheltered from the atmospheric agents.
-11-