Current measurement (only VC-86)
Currents of up to 400mA can be measured in the current measure-
ment area. The current measurement area is secured and thus pro-
tected against overloading.
Proceed as follows to measure dc currents:
- Turn range selction switch (10) to position "A"
- The polarity of the measuring figure concerned will be displayed
in the display together with the current measuring value in the dis-
play (6).
Proceed as follows to insert or measure alternating currents:
- Press button "S" (5) in the current measurement area, to change
to the AC area; if you press it again, you will switch back to the
DC area.
- The polarity of the measuring figure concerned will be displayed
in the display together with the current measuring value in the dis-
play (6).
Never operate the measurement device when it is
open.
Max-Hold Function (only VC-82)
The VC-82 has a MAX-Hold Function. If you press during a measu-
ring the MAX button (7), the item shows automatically the highest
measuring value on the LCD (6). To deactivate this funktion, press
MAX button (7) again.