Press key "LI" (7) during the voltage measurment (max. 250 V) for a
max. of 3 seconds. After release, the multimeter has the normal
measuring impedance of 10 .
Resistance measurement/continuity test
Make sure that all the circuit parts, switches and com-
ponents and other objects of measurement are dis-
connected from the voltage at all times.
Proceed as follows to measure resistance and for the acoustic con-
tinuity test:
- Turn range selction switch (10) to position " "
- Check the measuring lines for continuity by connecting both
measuring prods to one another. After that the resistance value
must read approx. 0 Ohm.
- Now connect the measuring prods to the object to be measured.
As long as the object to be measured is not high-resistive or is inter-
rupted, the measured value will be displayed in the display (6).
When you carry out a resistance measurement, make sure
that the measuring points which you contact with the
measuring prods are free from dirt, oil, soldering vamish
or similar Such circumstances can falsify the measured
result