6.6
wiring diagram
WARNING
!
Do not wire 110 volts to the valve or wall switch.
W725-0062 (NG)
W725-0063 (P)
(GAS VALVE)
note:
A USB power pack (not
supplied) can be used during a
power outage.
note:
The mandatory wall switch / thermostat should be connected to the piggyback connectors on the back of the
receiver.
W010-2763 (NG)
W010-2808 (P)
PILOT
BLUE
ACS
electrical information
W190-0195 (PF0 CONTROL BOARD)
PILOT SENSOR
SPARK ROD
WIRE HARNESS
ORANGE
GREEN
BLACK
WHITE
ALTERNATIVE
SWITCH
W750-0497
POWER CORD
(W750-0506)
OR
USB POWER
PACK
(NOT
SUPPLIED)
MANDATORY WALL
SWITCH / THERMOSTAT
W415-3036 / 05.07.21