Télécharger Imprimer la page

Indel B OFF T L 16 Instructions D'utilisation page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
LOW VOLTAGE PROTECTION
In order to prevent excessive battery depletion, a protection device shuts off the compressor in case of insufficient voltage
and turns it back on when the voltage in the system increases after the batteries have been charged.
BATTERY
DIGITAL
LEVEL
DISPLAY
Low
Medium
High
WARNING:
Before switching on the unit, always make sure that the batteries are in optimal condition
27
BATTERY PROTECTION
12VDC
CUT-OUT
CUT-IN
COMP. OFF
COMP. ON
9.6
10,6
11,1
12,1
11,8
12,8
OFF IS A BRAND OF INDELB
24VDC
CUT-OUT
CUT-IN
COMP. OFF
COMP. ON
21.3
22.7
22.3
23.7
24.3
25.7
EN

Publicité

loading