Maintenance
Engine oil change
The fi rst oil change should be carried out after 10 hours of operation.
Each of the following oil changes should be done after every 50 hours of opera-
tion.
1. Place a container under the unit to collect the used oil.
2. Unscrew the drain plug (A in fi gure 1).
3. Let the oil flow slowly to avoid splashing.
4. When the engine crankcase is empty, screw the drain plug back in.
5. Unscrew the fi ller cap / dipstick (B in fi gure 1).
6. FILLING OIL type SAE 10W-30. Fill oil up to the rim of the hole.
Crankcase capacity is 32 ounces (0.95 L).
7. Screw the fi ller cap / dipstick back on.
IMPORTANT:
Dispose of all used oils in accordance with environmental rules. Keep in a securely
sealed container, then take it to the nearest anteriorized disposal depot. DO NOT
throw into landfi ll or empty into the ground or sewer.
Pump oil change
Dispose of all used oils in accordance with environmental rules. Keep in a secu-
rely sealed container, then take it to the nearest anteriorized disposal depot.
DO NOT throw into landfi ll or empty into the ground or sewer.
The fi rst oil change should be carried out after 10 hours of operation.
Each of the following oil changes must be carried after every 200 hours of operation.
1. Place a container under the pump to collect the used oil.
2. Unscrew the drain plug.
3. Let the oil flow slowly to avoid splashing.
4. When the pump housing is empty, screw the drain plug back in.
5. Unscrew the fi ller cap / dipstick (C in fi gure 2).
6. FILLING OIL TYPE SAE 30 NON DETERGENT
FILL oil until is reaches middle of the sight transparent sight glass (D in fi gure 3).
7. Screw the fi ller cap / dipstick back on.
IMPORTANT:
Dispose of all used oils in accordance with environmental rules. Keep in a securely
closed container, then take it to the nearest authorized s disposal depot. Do not throw
in landfi ll or empty into the ground or sewer drains.