28
www.aeg.com
values around 0° C or drop below,
remove the remaining water from the
inlet hose and the drain pump.
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in
a container and let the water flow out
of the hose.
4. Empty the drain pump. Refer to the
emergency drain procedure.
14. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
14.1 Introduction
The appliance does not start or it stops
during operation.
First try to find a solution to the problem
(refer to the table). If the problem
persists, contact the Authorised Service
Centre.
In case of major problems, the acoustic
signals operate, the display shows an
alarm code and the Départ/Pause
button may flash continuously:
•
- The appliance does not fill with
water properly.
Start the appliance again by pressing
Départ/Pause button. After 5 seconds
the door will be unlocked.
•
- The appliance does not drain
the water.
•
- The appliance door is open or
not closed correctly. Please check the
door!
If the appliance is
overloaded, remove
some items from the
drum and/or keep
pressed the door while
touching the Départ/
Pause button until the
indicator
flashing (see the picture
below).
stops
5. When the drain pump is empty,
install the inlet hose again.
WARNING!
Make sure that the
temperature is higher than 0
°C before you use the
appliance again.
The manufacturer is not
responsible for damages
caused by low temperatures.
•
- The mains supply is unstable.
Wait until the mains supply is stable.
•
- No communication between
electronic elements of the appliance.
Switch it off and switch on again.
The programme was not finished
properly or the appliance stopped
too early. If the alarm code appears
again, contact the Authorised Service
Centre.
WARNING!
Deactivate the appliance
before carrying out any
check.