WARNING: These specifications could change for some countries due to special voltages. Verify the
rating plate of the machine before plugging it
Safety devices at "CE" models: Blade stop before 4 seconds. Buttons and safety devices on low
tension. Interlocking door system. On/off switch, non-voltage release
Finish......................: Stainless steel and anodised aluminium.
Pulley diameter, mm.
Blade length, mm.
Net weight, Kg.
NOTE: The specifications could be changed without prior notice.
14 ELECTRICAL DIAGRAMS
See page 22 and 23.
15 TECHNICAL SERVICE: VOLTAGE CHANGING
In order to change from 400V to 230V, or from 230V to 400V,
follow the next two operations.
Open the cover of the low tension
diagram):
1.- Connector nº1: Change depending on the desired voltage.
2.- Connector nº2: Change depending on the desired voltage.
ATTENTION: Both connections must be made on the
same voltage.
Close the cover of the low tension box (21).
The new voltage connection must be written at the rating
plate.
16 BLADE TURNS ON THE OPPOSITE DIRECTION, SOLUTION
1.- Unplug the machine.
2.- Open the low tension box (21).
3.- The network cables (13) colour blue, black and brown which go on connector at box (21) to
numbers 1, 3 and 5 must be interchanged two from the three. See the wiring diagram.
4.- Place the cover of the box (21).
17 FUSE CHANGE
1. - Unplugged the machine.
2. -Open the 24V plate box (21).
3. - Replace the fuse with a new one: For the F2 fuse the reference is 5 x 20, 250 V, 2 amperes and
for
the F3 fuse the reference is 5 x 20, 250 V , 0'5 amperes.
4. - Place the door cap again.