Télécharger Imprimer la page

Stiebel Eltron SHU 10 SLi Utilisation Et Installation page 17

Masquer les pouces Voir aussi pour SHU 10 SLi:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Preparations
7.1
Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
- Installation template
7.2
Accessories
The following accessories are available for sealed unvented op-
eration:
SHU 10 SLi
- SVMT safety assembly
- Water distribution tees
- WEH sensor tap
SH 10 SLi | SH 15 SLi
- Safety assembly KV 40 / KV 307
- Surface mounted safety assembly SRT 2
- Permanent connection set for 15 l appliances
8.
Preparations
Water installation
A safety assembly is required.
Taps/valves
Only install pressure taps in conjunction with a safety assembly.
8.1
Installation site
Material losses
!
Install the appliance in a room free from the risk of frost.
Material losses
!
Mount the appliance on the wall. The wall must have a
sufficient load-bearing capacity.
Note
Make sure that the appliance is
freely accessible for maintenance work.
Always install the appliance vertically and near the draw-off point.
8.1.1 SHU undersink installation with safety assembly
Material losses
!
The appliance is only suitable for undersink installation.
The water connections of the appliance point upwards.
www.stiebel-eltron.com
8.1.2 SH oversink installation with safety assembly
Material losses
!
The appliance is only suitable for oversink installation.
The water connections of the appliance point downwards.
35
comfor t
9.
Installation
Material losses
!
When using plastic pipework observe the extreme oper-
ating and fault conditions that can occur on the appliance
(see chapter "Installation / Specification / Extreme oper-
ating and fault conditions").
f Run the connections to the second tap on site, e.g. in 10 mm
copper pipe.
SHU 10 SLi
f To supply two washbasins, use the "water distribution
tees" (see chapter "Installation / Appliance description /
Accessories").
100-200
°C
82
35
65 Eco
55
Eco
55
65
85
°C
SHU 10 | SH 10 | SH 15 |
17

Publicité

loading

Ce manuel est également adapté pour:

Shu 10 sl gbSh 10 sliSh 15 sliSh 15 sl gb 3,3 kw