Télécharger Imprimer la page

Toro 37798 Manuel De L'utilisateur page 21

Masquer les pouces Voir aussi pour 37798:

Publicité

Les langues disponibles

Les langues disponibles

Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Loosen the jam nut.
2.
Engage the auger/impeller lever and hold it in
place
(Figure
28).
Figure 28
3.
Loosen or tighten the turnbuckle to adjust the
spring length to 7 cm (2-3/4 inches) as shown
in
Figure
29.
Figure 29
1. Jam nut
2. Turnbuckle
4.
Tighten the jam nut
there is slight tension on the cable.
5.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.
3. Spring
4. 7 cm (2-3/4 inches)
(Figure
29), ensuring that
Checking the
Auger-Gearbox-Oil Level
Service Interval: Yearly—Check the auger-gearbox
1.
Move the machine to a level surface.
2.
Clean the area around the pipe plug
g001013
1. Pipe plug
3.
Remove the pipe plug from the gearbox.
4.
Check the oil level in the gearbox. The oil should
be 9.5 mm (3/8 inch) below the filler opening.
5.
If the oil level is low, add GL-5 or GL-6, SAE
80-90 EP gear oil lubricant to the gearbox until
the oil level is 9.5 mm (3/8 inch) below the filler
opening.
Note:
Do not use synthetic oil.
6.
Install the pipe plug in the gearbox.
g031000
21
oil and add oil if necessary.
Figure 30
(Figure
30).
g016782

Publicité

loading

Ce manuel est également adapté pour:

Power max 826 oxePower max 824 oe37799