Description; Preparation Before Use; Checking The Oil Level - SDMO TECHNIC 10000 E C Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

2. Description

1
Earth connection
2
Oil filler cap
3
Oil draining screw
4
Fuel gauge
5
Fuel tank plug
1
Oil gauge
2
Upper limit of gauge
1
Fuel tap
1
Wheel
2
Air filter cover
1
Spark plug cap

3. Preparation before use

3.1. Positioning the generating set for operation
Choose a site that is clean, well ventilated and sheltered from bad weather. Place the generating set on a flat, horizontal surface which
is firm enough to prevent the set sinking down (under no circumstances should the set tilt in any direction by more than 10°). Store the
additional supplies of oil and fuel within close proximity, whilst maintaining a certain distance for safety.
European Union Member States and affiliated countries: This equipment is not intended for use outside an enclosure that significantly
affects sound transmission (exhaust gases must be discharged outdoors and suitable ventilation must be provided to guarantee that
persons or animals in the vicinity of the equipment will not be affected).
3.2. Earthing the generating set
Danger
To connect the set to the ground: Attach a 10 mm
driven 1 meter into the ground.

3.3. Checking the oil level

Before starting–up the generating set, always check the engine oil level.
Make sure the recommended oil is used (see § Specifications) and use a funnel to fill-up to the maximum limit
indicated on the dipstick.
Attention
Allow the generating set to cool down for at least 30 minutes before checking the oil level.
Retract the oil-level dipstick (fig. B - mark 1) and wipe it.
Replace the oil-level dipstick and pull it out again.
Check the level visually. It should be within the upper limit shown on the dipstick (fig. B – mark 2) and the lower limit on the dipstick
(fig. B - mark 3). Correct as required.
Replace the dipstick.
Wipe off excess oil with a clean cloth, check that there are no leaks.
3.4. Checking the fuel level
Danger
Check the fuel level on the fuel gauge (fig. A - No. 4). If necessary, fill-up:
Unscrew the fuel tank filler cap (fig. A - No. 5).
Fill the tank until the fuel gauge shows "F ", using the funnel and taking care not to spill any fuel.
Only use clean fuel without any water.
Do not overfill the tank (there should not be any fuel in the filler neck).
After filling-up, always check that the fuel tank filler cap is tightly closed.
If any fuel has been spilled, make sure that it has dried out and that any associated fumes have dissolved in the
Attention
atmosphere before starting-up the generator set.
Screw down the fuel tank filler cap tightly.
6
Fuel tap
7
Air filter
8
Choke
9
Hare – tortoise switch
10
Ignition key
3
Lower limit of gauge
4
Oil filter
2
Fixing clamps
3
Filtration elements nut
4
Paper element
2
Spark plug
The generating sets supply electrical current when in operation: risk of electrocution.
Connect the generating set to the ground at each use.
2
copper wire to the set's earth connection and to a galvanised steel earthing rod
Filling with fuel must be carried out when the engine is switched off and as per the safety
instructions (see § Filling with fuel).
Figure A
Figure B
Figure C
Figure D
Figure E
11
Circuit breakers
12
Electrical sockets
13
Starter battery
14
Exhaust silencer
15
Working hours counter
3
Fuel filter
5
Foam element

Publicité